PENGARUH TEKANAN OPERASI SEA WATER REVERSE OSMOSIS TERHADAP KUALITAS PRODUK MELALUI SIMULASI VEOLIA DAN DATA OPERASIONAL DI PLTU PACITAN

Authors

  • Rama Devana Putra Putra Jurusan Teknik Kimia, Politeknik Negeri Malang, Jl. Soekarno Hatta No.9, Malang 65141, Indonesia
  • Ariani Ariani Jurusan Teknik Kimia, Politeknik Negeri Malang, Jl. Soekarno Hatta No. 9, Malang 65141, Indonesia
  • Jati Kamajaya PT. PLN Nusantara Power Unit Pembangkitan Pacitan Jalan Pacitan – Trenggalek KM 55, Desa Sukorejo, Kec. Sudimoro, Pacitan, Indonesia

DOI:

https://doi.org/10.33795/distilat.v12i2.8020

Keywords:

Sea Water Reverse Osmosis, Konduktivitas Air, Tekanan Operasi, Simulasi Veolia

Abstract

Analisis efisiensi membran Sea Water Reverse Osmosis (SWRO) pada Water Treatment Plant di PLTU Pacitan penting dilakukan untuk memastikan kinerja optimal sistem desalinasi dalam menyediakan air umpan berkualitas tinggi bagi proses pembangkitan listrik serta menekan biaya operasional dan meningkatan keandalan sistem. Penelitian ini menganalisis pengaruh tekanan operasi pada sistem SWRO terhadap konduktivitas produk yang dihasilkan. Analisis dilakukan dengan membandingkan data operasional aktual dengan hasil simulasi menggunakan perangkat lunak bawaan dari pemasok membran, yaitu software Veolia. Data primer berupa konduktivitas diambil pada rentang tekanan 25–47 bar melalui pengukuran permeat kumulatif selama periode September hingga November 2024. Hasil menunjukkan adanya korelasi negatif antara tekanan dan konduktivitas: peningkatan tekanan cenderung menurunkan konduktivitas produk (contoh: pada 47 bar → 754–914 μS/cm; pada 25 bar → 4794–9567 μS/cm). Namun demikian, ditemukan penyimpangan rata-rata sebesar 66% antara data aktual dan simulasi, yang mengindikasikan adanya penurunan kinerja membran akibat proses penuaan (aging), faktor pengotor (fouling), serta karena sudah mendekati masa akhir penggunaan (lifetime). Temuan ini menekankan pentingnya pemeliharaan membran secara berkala dan membuka peluang peningkatan efisiensi sistem SWRO secara rutin dan berkelanjutan.

References

R. A. Pratama dan M. Ikhsan, “Penerapan Forescating Konsumsi Listrik terhadap Kenaikan Pelanggan dengan Double Exponential Smoothing Holt’s,” Jurnal SIMETRIS, vol. 13, 2022.

S. Johan dan A. M. Ginting, “Determinasi Konsumsi Listrik di Indonesia,” Media Ekonomi, vol. 30, no. 1, hal. 106–117, Sep. 2022.

Ridhani dan M. Ilhamsyah Siregar, “Forescating Konsumsi Listrik di Indonesia,” (JIM EKP) Fakultas Ekonomi dan Bisnis Universitas Syiah Kuala, vol. 6, no. 3, hal. 195–204, 2021.

Pemerintah Pusat Indonesia, Peraturan Presiden (Perpres) Nomor 71 Tahun 2006 tentang Penugasan Kepada PT Perusahaan Listrik Negara (Persero) Untuk Melakukan Percepatan Pembangunan Pembangkit Tenaga Listrik yang Menggunakan Batubara. Indonesia: Sekretariat Kabinet Republik Indonesia, 2006.

T. Altmann, P. J Buijs, A.S.F. Farinha, V.R.P. Borges, N. M. Farhat,J.S. Vrouwenvelder, dan Ratul Das, “Seawater Reverse Osmosis Performance Decline Caused by Short-Term Elevated Feed Water Temperature,” Membranes (Basel)., vol. 12, no. 8, Art. no. 792, Aug. 2022.

C. Niu, X. Li, R. Dai, dan Z. Wang, “Artificial intelligence-incorporated membrane fouling prediction for membrane-based processes in the past 20 years: A critical review,” Water Res., vol. 216, Art. no. 118299, 2022.

A. M. Mushtaha, M. Shatat, K. Arakelyan, O. Shatat, T. Forster, dan A. Mushtaha, “Water Desalination in the Gaza Strip: Al Salam RO Brackish Water Desalination Plant Case Study,” Proceedings of the 40th WEDC International Conference: Local Action with International Cooperation to Improve and Sustain Water, Sanitation and Hygiene Services, Loughborough, United Kingdom, 2017.

S. Duranceau, Reverse Osmosis and Nanofiltration Technology: Inorganic, Softening and Organic Control. Isle of Palms, SC, USA: American Membrane Technology Association, 2001.

S. El Aimani, “Modeling of Reverse Osmosis Water Desalination Powered by Photovoltaic Solar Energy,” Green Energy and Environmental Technology, vol. 2, Feb. 2023.

L. Henthorne dan B. Boysen, “State-of-the-art of reverse osmosis desalination pretreatment,” Desalination, vol. 356, pp. 129–139, 2015.

Y. A. Tayeh, “A Comprehensive Review of Reverse Osmosis Desalination: Technology, Water Sources, Membrane Processes, Fouling, and Cleaning,” Desalination and Water Treatment, vol. 320, Art. no. 100882, 2024.

E. Coutinho de Paula dan M. C. S. Amaral, “Extending the Life-Cycle of Reverse Osmosis Membranes: A Review,” Waste Management & Research, vol. 35, no. 5, pp. 456–470, 2017.

M. Elimelech and W. A. Phillip, “The Future of Seawater Desalination: Energy, Technology, and the Environment,” Science, vol. 333, no. 6043, hal. 712–717, 2011.

R. Bagaskara, “Menghitung Neraca Massa dan Efisiensi Kinerja Sea Water Reverse Osmosis (SW3OHR LE-400) PT. PLN Nusantara Power UP Paiton Unit 9,” Diploma thesis, Universitas Pembangunan Nasional "Veteran" Yogyakarta, Yogyakarta, 2024.

M. Safitri, “Valuasi Performa Sea Water Reverse Osmosis pada Water Treatment Plant Unit 3A PT. Sumber Segara Primadaya (PLTU) Cilacap,” Diploma thesis, Universitas Pembangunan Nasional "Veteran" Yogyakarta, Yogyakarta, 2022.

M. Kurihara, T. Sasaki, K. Nakatsuji, M. Kimura, dan M. Henmi, “Low pressure SWRO membrane for desalination in the Mega-ton Water System,” Desalination, vol. 368, pp. 135–139, Jul. 2015.

DuPont Water Solutions, FilmTec™ Reverse Osmosis Membranes Technical Manual, Version 17. Wilmington, DE, USA: DuPont Water Solutions, 2024.