Implementasi Alat Pengujian Relay 48 dan 220 VAC Untuk Mendukung Pratikum di Bengkel Listrik 4

Authors

  • Arif Andrianto Politeknik Negeri Malang
  • Susilo Politeknik Negeri Malang
  • Agus Andryanto Politeknik Negeri Malang
  • Ilham Syarif Hidayatullah Politeknik Negeri Malang
  • Nanang Setio Pambudi Politeknik Negeri Malang
  • Saiful Andani Politeknik Negeri Malang

DOI:

https://doi.org/10.33795/elposys.v13i1.8920

Keywords:

Relay, Testing Tools, Transformer, Engineering Practicum, Electrical Workshop

Abstract

The Electrical Workshop 4 course at the State Polytechnic of Malang is a form of practicum that aims to improve students' competence in understanding and implementing electrical systems, including the use of relays as regulatory components in automatic control systems. One of the obstacles often encountered is a relay that is damaged or does not function before being used in a student project, causing delays in the learning process and increasing the workload of lecturers in manual che cking. To overcome these problems, this study aims to design and realize a 48 VAC and 220 VAC relay testing tool that can be used as a practicum aid in Electrical Workshop 4. This tool is designed using a step-down transformer to reduce the voltage from 220 VAC to 48 VAC, and is equipped with 8-pin and 11-pin relay sockets for the on-delay and off-delay relay types. The push button is used as a trigger for relay activation, and the indicator light functions as a marker for the success of the relay. The assembly and testing process of the tool was carried out in the Electrical Workshop, and the implementation results showed that the tool was able to function properly according to plan and could be operated by students. In addition, this research also produced a user manual and a scientific article that has been submitted to the Elposys journal. 

References

A. M. R. R. Faiz and M. H. Putranto, “Trainer transformator daya dilengkapi dengan sistem monitoring,” unpublished.

M. Yudha, A. PLTA, and T. Lebong, “Rancang bangun alat penguji relay 220 VAC portable pada cubicle panel unit 6 PLTA TES,” 2021. [Online]. Available: https://blogpenemu.blogspot.com

R. M. W. N. S. P. Santosa, “Rancang bangun alat pintu geser otomatis menggunakan motor DC 24 V,” vol. 9, no. 1, p. 6, 2021.

M. Saleh and M. Haryanti, “Rancang bangun sistem keamanan rumah menggunakan relay,” J. Teknol. Elektro, vol. 8, no. 3, pp. 181–186, 2017. [Online]. Available: http://publikasi.mercubuana.ac.id/index.php/jte/article/download/2182/1430

M. A. Nugraha et al., “Rancang bangun alat ‘spinner pulling oil’ sebagai pengentas minyak otomatis dalam peningkatan mutu abon ikan patin (Pangasius pangasius),” J. Teknol. Pertan., vol. 15, no. 2, pp. 103–110, 2014.

D. Peterson, “Explaining industrial timers: On delay and off delay,” Control Automation, 2023. [Online]. Available: https://control.com/technical-articles/explaining-industrial-timers-on-delay-and-off-delay/

Suryono and Supriyati, “Rancang bangun timer terprogram dengan tampilan lampu tiga warna sebagai pewaktu pada kegiatan seminar,” Orbith, vol. 15, no. 3, pp. 120–129, 2019.

A. K. Sawhney, A Course in Electrical and Electronic Measurements and Instrumentation. New Delhi, India: Dhanpat Rai & Co., 2015.

S. K. Bhattacharya and S. Chatterjee, “Design and implementation of relay testing system for industrial applications,” Int. J. Electr. Eng. Technol., vol. 11, no. 2, pp. 45–52, 2020.

M. S. Ali, M. R. Islam, and M. A. Hossain, “Development of an automatic relay testing device for power system protection,” IEEE Access, vol. 8, pp. 134567–134575, 2020.

P. K. Dash, S. Mishra, and G. Panda, “A novel approach for testing and monitoring of protective relays,” Electr. Power Syst. Res., vol. 143, pp. 438–445, 2017.

R. C. Dorf and J. A. Svoboda, Introduction to Electric Circuits, 9th ed. Hoboken, NJ, USA: Wiley, 2014.

H. Saadat, Power System Analysis, 3rd ed. New York, NY, USA: McGraw-Hill, 2010.

B. Kasztenny, N. Fischer, and M. Adamiak, “Advancements in protective relay testing and commissioning,” IEEE Trans.

Power Del., vol. 32, no. 4, pp. 1825–1833, Aug. 2017.

T. S. Madhava Rao, “Microcontroller-based relay testing and fault detection system,” Int. J. Eng. Res. Technol. (IJERT), vol. 6, no. 5, pp. 321–325, 2017.

Downloads

Published

09-04-2026

How to Cite

Andrianto, A., Susilo, Andryanto, A., Hidayatullah, I. S., Nanang Setio Pambudi, & Andani, S. (2026). Implementasi Alat Pengujian Relay 48 dan 220 VAC Untuk Mendukung Pratikum di Bengkel Listrik 4. Elposys: Jurnal Sistem Kelistrikan, 13(1), 13–17. https://doi.org/10.33795/elposys.v13i1.8920