Trainer Kit Tegangan Langkah Berbasis Arus Gangguan sebagai Media Pembelajaran Sistem Pembumian
DOI:
https://doi.org/10.33795/elposys.v13i2.9532Keywords:
electrical safety, Step voltage, trainer kit, grounding system, electrical safety, fault current, educational practicum.Abstract
Human safety and electrical equipment reliability in power installations are strongly influenced by step voltage generated by fault currents flowing into the ground. The resulting ground potential distribution, which depends on fault current magnitude, grounding system characteristics, soil resistivity, and distance from the fault point, determines the level of electrical hazard to humans. This study aims to design, develop, and evaluate a step voltage trainer kit based on fault current injection as a practical learning media for understanding grounding system behavior and electrical safety principles. The research methodology involved field measurement of grounding electrode resistance, calculation of soil resistivity, design and fabrication of the trainer kit, and experimental testing under various fault current levels and measurement distances, both with and without a grounding system. Experimental results indicate that step voltage reaches its maximum value at locations closest to the fault point and decreases significantly with increasing distance, while the measured fault current remains relatively stable across different distances. The application of a low-resistance grounding system effectively reduces step voltage and flattens the ground potential gradient, thereby mitigating electrical hazard risks. The integration of field-based grounding resistance data into the soil simulator enables the trainer kit to realistically represent actual installation conditions. These findings demonstrate that the developed step voltage trainer kit provides a reliable, empirical, and safe educational platform for visualizing the relationship between fault current, soil resistivity, grounding systems, and step voltage hazards in electrical power installations.
References
IEEE Std 80-2013 (Revision of IEEE Std 80-2000), Incorporating IEEE Std 80-2013/Cor 1-2015, IEEE Guide for Safety in AC Substation Grounding, May 2015.
IEC 60479-1:2018, Effects of Current on Human Beings and Livestock—Part 1: General Aspects. Geneva, Switzerland: International Electrotechnical Commission, 2018.
Badan Standardisasi Nasional, Persyaratan Umum Instalasi Listrik (PUIL) 2020—Bagian 5-54: Pemilihan dan Pemasangan Peralatan Listrik—Susunan Pembumian dan Konduktor Proteksi, SNI 0225-5-54:2020.
M. Nassereddine, A. Hellany, J. Risk, T. Famakinwa, and M. Nagria, “Advanced earth grid monitoring for HV network safety compliance,” Aust. J. Electr. Electron. Eng., vol. 22, no. 3, pp. 504–517, Jul. 2025, doi: 10.1080/1448837X.2024.2414476.
M. Alexandru, L. Czumbil, A. Polycarpou, H. Nouri, R. Andolfato, and D. D. Micu, “Mitigation of transient ground potential rise in gas insulated substations during very fast transient overvoltage,” Electr. Power Syst. Res., vol. 207, p. 107824, Jun. 2022, doi: 10.1016/j.epsr.2022.107824.
M. Nazari, R. Moini, S. Fortin, F. P. Dawalibi, and F. Rachidi, “Impact of Frequency-Dependent Soil Models on Grounding System Performance for Direct and Indirect Lightning Strikes,” IEEE Trans. Electromagn. Compat., vol. 63, no. 1, pp. 134–144, Feb. 2021, doi: 10.1109/TEMC.2020.2986646.
81-2025 - IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System. IEEE, 2025.
O. E. Gouda, A. Z. El Dein, S. Yassin, M. Lehtonen, and M. M. F. Darwish, “Investigation of soil resistivity impacts on the electrodes of grounding system subjected to lightning strikes,” IET Gener. Transm. Distrib., vol. 18, no. 21, pp. 3392–3406, Nov. 2024, doi: 10.1049/gtd2.13287.
H. Farooq, W. Ali, H. Iqbal, A. Rasool, I. A. Sajjad, and A. A. Noon, “Evaluation of the Safety Performance of a 500-kV AC Substation Grounding Using IEEE Standard 80-2013,” ELECTRICA, vol. 21, no. 2, pp. 225–234, May 2021, doi: 10.5152/electrica.2021.20086.
X.-B. Nguyen, N.-N. Nguyen, and P.-T. Vu, “Numerical Simulation of Potential Distribution in Grounding Systems Using the Finite Difference Matrix Operators Approach with Non-Uniform Mesh,” Energies, vol. 18, no. 21, p. 5780, Nov. 2025, doi: 10.3390/en18215780.
F. Qiu, J. Cao, Y. Ding, Y. Du, and Z. Du, “Simulation of Ground Potential Distribution around Grounding Grids using a PEEC Method,” in 2022 IEEE/IAS 58th Industrial and Commercial Power Systems Technical Conference (I&CPS), Las Vegas, NV, USA: IEEE, May 2022, pp. 1–5. doi: 10.1109/ICPS54075.2022.9773799.
M. Parhamfar, A. F. Güven, M. Bajaj, and M. S. Geremew, “Optimized grounding design for 220/110 kV substations using CYMGRD: A simulation-based approach for safe and cost-efficient energy infrastructure,” Energy Explor. Exploit., vol. 44, no. 4, pp. 2072–2096, Jul. 2026, doi: 10.1177/01445987261417706.
S. Alsaleh, A. Tepljakov, A. Kose, J. Belikov, and E. Petlenkov, “ReImagine Lab: Bridging the Gap Between Hands-On, Virtual and Remote Control Engineering Laboratories Using Digital Twins and Extended Reality,” IEEE Access, vol. 10, pp. 89924–89943, 2022, doi: 10.1109/ACCESS.2022.3199371.
Y. Dan, J. Yin, J. Yang, and H. Yang, “Influence analysis of calculated horizontally layered soil parameters on grounding parameters,” High Volt., vol. 8, no. 2, pp. 421–430, Apr. 2023, doi: 10.1049/hve2.12257.
N. Permal, M. Osman, A. M. Ariffin, and M. Z. Abidin Ab Kadir, “Effect of Non-Homogeneous Soil Characteristics on Substation Grounding-Grid Performances: A Review,” Appl. Sci., vol. 11, no. 16, p. 7468, Aug. 2021, doi: 10.3390/app11167468.
J. Liu, “Analysis of Current Density in Soil for Resistivity Measurements and Electrical Grounding Designs,” J. Electr. Electron. Eng., vol. 5, no. 5, p. 198, 2017, doi: 10.11648/j.jeee.20170505.17.
H. Budiman and B. Sirait, “Evaluasi Tegangan Sentuh Tegangan Langkah Dan Tegangan Pindah Gitet 275 Kvbengkayang”,https://jurnal.untan.ac.id/index.php/j3eituntan/issue/view/1371, https://doi.org/10.26418/j3eit.v8i2.
Eva Kurnia Yulyawan and Mas Ahmad Baihaqi, “Studi Evaluasi Pengetanahan Gardu Induk Dengan Adanya Perubahan Tegangan Sistem Dari 70 kV Menjadi 150 kV,” Elposys J. Sist. Kelistrikan, vol. 9, no. 1, pp. 18–23, Feb. 2023, doi: 10.33795/elposys.v9i1.607.