Analisis Kualitas Daya Beban 1-Fasa Non-Linear Pada Computer Assisted Test CPNS

Authors

  • Binar Surya Gumilang Gumilang Politeknik Negeri Malang
  • Masramdhani Saputra
  • Asfari Hariz Santoso
  • Saddani Djulihenanto

DOI:

https://doi.org/10.33795/elposys.v10i3.4443

Keywords:

Harmonics, Power Quality, Generator, Derating Factor

Abstract

Along with technological advances in the digital era like today, which is growing faster, it has an impact on many fields. One field that has used a lot of technological developments is the CPNS Test which is based on the CAT (Computer Assisted Test) and uses many a lot of laptop/computer devices to support the implementation of the test. The many uses of computers, especially during the recruitment test, influence the quality of electrical power due to the typical character of the PC/laptop load, which is a non-linear single-phase load which results in neutral currents or currents containing harmonics. This is because the load on the pc/laptop has electronic components such as semiconductors where there is a switching process that creates an impure sinusoidal wave that causes harmonics. In the case study, the implementation of the CPNS CAT with the use of PC/laptop devices will certainly cause a fairly high THD and affect the electric current/power source. The thing that needs to be considered with a high THD and the supply of electricity from the generator is the effect on the performance of the generator and the influence of the generator’s lifetime. Briefly, the loading of the data is to reduce the derating generator set by 6,717 kVa so that the safe loading is 23.28 kVa with a maximum capacity of 30 kVa generator. Synchronous generator loading is recommended at 81% of its nominal value with a current THD of 50%.

References

Rashid, Muhammad H. 1999, ElektronikaDaya. Jilid 1. Jakata : PTPrenhallindo

Lander C.W., 1993, Power Electronics, Third Edition, Mc Graw-Hill NewDelhi India

IEEE Std 519-1992, 1993, Recommended Practice And Requirements For Harmonic Control In Electric Power System, Institute Of Electrical AndElectronic Engineers, Inc. 1993.

Sankaran, C. 2002. Power Quality. Florida : CRC Press LLC

Hermawan, A., Sakti, G. H., Ronilaya, F., & Hermawan, S. L. (2022). Audit Energi dan Penilaian Kualitas Daya Pada Penerangan Jalan Umum Politeknik Negeri Malang. Elposys: Jurnal Sistem Kelistrikan, 9(3), 199-204.

Saputra, M., Ridzki, I., Wiwaha, S. S., & Djulihenanto, S. (2023). Implementation of Power Factor Correction using Asynchronous Boost Converter on Single Phase Full-Bridge Diode. Jurnal EECCIS (Electrics, Electronics, Communications, Controls, Informatics, Systems), 17(2), 34-40.

Hubert, Charles . 1982, “Electric Circuits AC/DC”. McGraw-Hill InternasionaL.

Santoso, A. H., Rizka, E., & Mukti, H. (2022). Analisis Pembebanan Terhadap Perkiraan Umur Transformator Distribusi 20 kV Penyulang Lowokwaru di PT. PLN (PERSERO) UP3 Malang. Elposys: Jurnal Sistem Kelistrikan, 9(3), 121-126.

Ananto, R. A., Duanaputri, R., Santoso, A. H., & Hakim, M. F. (2023). Perencanaan Desain Single Tuned Passive Filter Harmonisa Pada AC Microgrid Turbin Tenaga Angin. Elposys: Jurnal Sistem Kelistrikan, 10(1), 78-81.

Aziz, A. S., Tajuddin, M. F. N., Adzman, M. R., Ramli, M. A., & Mekhilef, S. (2019). Energy management and optimization of a PV/diesel/battery hybrid energy system using a combined dispatch strategy. Sustainability, 11(3), 683.

Hidayat, M. N., Yustika, L. M., Putri, R. I., & Nurhadi, S. (2020, September). Design and analysis of a multiple input single output converter to support the development of DC house in Indonesia. In AIP Conference Proceedings (Vol. 2255, No. 1). AIP Publishing.

Mumtaz, F. N., Sudiharto, I., & Qudsi, O. (2022). Shunt Active Power Filter untuk Meredam Harmonisa Beban Non-Linear Satu Fasa. Electrician: Jurnal Rekayasa dan Teknologi Elektro, 16(1), 9-19.

Alfarezy, D. (2023). ANALISIS HARMONISA PADA BAGIAN AUXILARY PLTU X (Doctoral dissertation, ITN MALANG).

Duanaputri, R., Hakim, M. F., Rachman, R. A., & Nadhiroh, N. (2023). Analisis Kestabilan Transien Akibat Penambahan Generator di Pabrik Gula. Elposys: Jurnal Sistem Kelistrikan, 10(2), 118-123.

Ananto, R. A., Duanaputri, R., Santoso, A. H., & Hakim, M. F. (2023). Perencanaan Desain Single Tuned Passive Filter Harmonisa Pada AC Microgrid Turbin Tenaga Angin. Elposys: Jurnal Sistem Kelistrikan, 10(1), 78-81.

Downloads

Published

2023-10-31

How to Cite

Gumilang, B. S. G., Masramdhani Saputra, Asfari Hariz Santoso, & Saddani Djulihenanto. (2023). Analisis Kualitas Daya Beban 1-Fasa Non-Linear Pada Computer Assisted Test CPNS. Elposys: Jurnal Sistem Kelistrikan, 10(3), 195–200. https://doi.org/10.33795/elposys.v10i3.4443