Studi Ekonomis Implementasi Kapasitor Dengan Detuned Reactor Untuk Meningkatkan Efisiensi Faktor Daya
DOI:
https://doi.org/10.33795/elposys.v11i1.4638Keywords:
Power factor; Capacitor bank; Electrical energyAbstract
The use of electrical energy plays a vital role in supporting the continuity of production processes in industrial environments. One critical area that heavily relies on electrical power supply is in the planning of installing a capacitor bank with a detuned reactor. The primary objective of this planning is to enhance the power factor (cos φ) from 60% to 85.2% during full-load operations and up to 94% when operating as per demand simulations. The evaluation of power quality from the implementation of the Capacitor with Detuned Reactor is conducted through simulations using ETAP 12.6.0 software.The simulation results from ETAP 12.6.0 produce comparative graphs between buses equipped with the Capacitor with Detuned Reactor and buses without it, both during full-load operational conditions and when only operating in simulations. The information derived from the simulation provides a deeper insight into the impact of installing the capacitor with detuned reactor on power factor and power quality within this industrial environment. With this understanding, further steps can be taken to optimize the electrical power system within the industrial setting.
References
Kusko, M., & Božek, P. Power factor correction and harmonics filtering in electrical power system. In 2017 International Conference on Optimization of Electrical and Electronic Equipment (OPTIM) IEEE. (pp. 682-687). 2017.
Saad, H., & Farag, H. E.. Power factor correction in electric power systems: A review. International Journal of Electrical Power & Energy Systems, 105, 256-267. 2019.
Y.-T. Hsiao, “Design of Filters for Reducing Harmonic Distortion and Correcting Power Factor in Industrial Distribution Systems,” Tamkang Journal of Science and Engineering, vol. 4, pp. 193–199, Sep. 2001.
Hossain, M. S., & Negnevitsky, M. Integration of a hybrid energy storage system and capacitor banks for power factor correction and energy management in a distribution network. Applied Energy, 173, 99-108. 2016.
Thallam Tharun Kumar, & D. C. Kiran Kumar.. Power Factor Correction Using Capacitor Banks. International Journal of Engineering Research and General Science, 4(3), 366-372. 2016.
Das, S. K., & Deb, S. Design and analysis of harmonic filters for power factor improvement in a steel industry. International Journal of Scientific & Engineering Research, 7(6), 392-397. 2016.
Angrish, R., & Bhatia, M. S. Power factor correction in electrical distribution system: A case study. Procedia Technology, 25, 507-514. 2016.
Saini, J. S., & Saini, A. Simulation and design of power factor correction with passive filters. International Journal of Computer Applications, 118(22). 2015)
Singh, K. K., & Singh, R. K. Review on power factor improvement techniques. International Journal of Engineering Research & Technology, 4(1), 1404-1407. (2015).
Rashidi, J., & Fahri, AEconomic analysis of power factor correction using capacitor bank for industrial loads. In 2014 IEEE PES Transmission & Distribution Conference and Exposition-Asia and Pacific (T&D Asia) (pp. 1829-1833). IEEE. . 2014.
R. A. Ananto, R. Duanaputri, A. H. Santoso, and M. F. Hakim, “Perencanaan Desain Single Tuned Passive Filter Harmonisa Pada AC Microgrid Turbin Tenaga Angin,” Elposys: Jurnal Sistem Kelistrikan, vol. 10, no. 1, pp. 78–81, 2023.
W. Ko and M. Tuomainen, “Design and application of a single‐tuned passive harmonic filter to suppress harmonic distortion and resonance for railway traction power systems—A case study,” IET Electrical Systems in Transportation, vol. 12, no. 2, pp. 153–164, 2022.
V. N. Jayasankar and U. Vinatha, “Backstepping controller with dual self-tuning filter for single-phase shunt active power filters under distorted grid voltage condition,” IEEE Transactions on Industry Applications, vol. 56, no. 6, pp. 7176–7184, 2020.
D. Melo, J. L. R. Pereira, A. M. Variz, and P. F. Ribeiro, “Allocation and sizing of single tuned passive filters in three-phase distribution systems for power quality improvement,” Electric power systems research, vol. 180, p. 106128, 2020.