Efektivitas Mutasi Transformator Dalam Mengatasi Fluktuasi Beban Pada Trafo Distribusi ULP Bululawang

Authors

  • Harrij Mukti K. Politeknik Negeri Malang
  • Rachmat Sutjipto Politeknik Negeri Malang
  • Vidiasih Politeknik Negeri Malang

DOI:

https://doi.org/10.33795/elposys.v11i2.5187

Keywords:

Least Square, Loading, Mutation,Protection, Transformer

Abstract

Transformer is a very important component in the distribution of electricity from the distribution substation to consumers. Overloading and underloading of transformers can lead to significant inefficiencies and increased losses in the electrical distribution system. Based on data measurement of the ULP Bululawang transformer in 2022, it was found that the C0177 transformer (100 KVA) was overloaded (88.4%) and the C0254 transformer (160 KVA) was underloaded (21.4%). Load forecasting for 2027 predicts that the C0177 transformer load will reach 107%, causing overheating, while the C0254 transformer will remain underloaded at 23.68%. To address these issues, a transformer mutation was proposed. This study aims to evaluate the effectiveness of transformer mutation in redistributing loads and improving efficiency. The method involved measuring transformer loads before and after mutation and using the Least Square method for load forecasting. Post-mutation measurements showed the C0177 transformer load reduced to 62.6% and the C0254 transformer load increased to 37%. These results indicate that the transformer mutation significantly balanced the load distribution. The study also adjusted the protection settings, including FCO, output cable, main switch, PHB-TR, and NH Fuse output cable. The findings suggest that transformer mutation can effectively address load imbalances, improve operational efficiency, and reduce power losses in the distribution system.

References

M. Adam, P. Harahap, and M. Ridho Nasution, “Analisa Pengaruh Perubahan Kecepatan Angin Pada Pembangkit Listrik Tenaga Angin (PLTA) Terhadap Daya Yang Dihasilkan Generator DC,” RELE (Rekayasa Elektr. dan Energi) J. Tek. Elektro, vol. 2, no. 1, pp. 30–36, Aug. 2019, doi: 10.30596/RELE.V2I1.3648.

A. Ulinuha and W. A. Widodo, “Rancang Bangun Pembangkit Listrik Tenaga Angin Skala Mikro Untuk Keperluan Penerangan Jalan,” Proceeding 7th Univ. Res. Colloq. 2018 Bid. Tek. dan Rekayasa, pp. 128–135, 2019.

A. Muhammad, H. Tumaliang, and S. Silimang, “Analisa Rugi-Rugi Energi Listrik Pada Jaringan Distribusi (JTM) Di PT. PLN (Persero) Area Gorontalo,” J. Tek. Elektro dan Komput., vol. 7, no. 3, pp. 295–302, 2018, doi: 10.35793/JTEK.V7I3.23634.

K. Kartika and M. Misriana, “Sistem Monitoring Transformator Distribusi Berbasis XBee Pro,” J. Litek J. List. Telekomun. Elektron., vol. 15, no. 2, pp. 29–37, Sep. 2018, doi: 10.30811/LITEK.V15I2.1662.

M. T. NUGRAHA and D. FAUZIAH, “Penanggulangan Overload Transformator Distribusi dengan Metode Uprating di Gardu PNBS 20 KV ULP Pangandaran,” Pros. Semin. Nas. Energi, Telekomun. dan Otomasi, pp. 293–304, 2021.

I. W. S. Yasa, “MENGATASI TRANSFORMATOR OVERLOAD DENGAN METODE UPRATING TRANSFORMATOR PADA GARDU DISTRIBUSI,” J. Kaji. Tek. Elektro, vol. 8, no. 2, pp. 82–91, Aug. 2023, doi: 10.52447/JKTE.V8I2.6745.

N. M. Seniari, M. N. Fadli, and I. M. Ginarsa, “ANALISIS RENCANA PEMASANGAN TRANSFORMATOR SISIPAN PADA SALURAN TRANSFORMATOR DISTRIBUSI PENYULANG PAGUTAN (Studi Kasus: Transformator Distribusi AM097 Di Jalan Banda Seraya, Pagesangan, Kota Mataram),” DIELEKTRIKA, vol. 7, no. 1, pp. 56–63, Feb. 2020.

R. Sutjipto, H. Sungkowo, Epiwardi, and D. D. Kharisma, “Analisis Penggunaan Transformator Sisipan Untuk Mengatasi Rugi Tegangan dan Pembebanan Lebih,” Elposys J. Sist. Kelistrikan, vol. 10, no. 3, pp. 172–177, Oct. 2023, doi: 10.33795/ELPOSYS.V10I3.4223.

I. M. A. Wiryawan, I. P. Sutawinaya, and I. W. R. Sutrawan, “ANALISIS PERBANDINGAN ANTARA PENGGUNAAN TRANSFORMATOR SISIPAN DAN UPRATING TRANSFORMATOR DALAM MENANGGULANGI DROP TEGANGAN PADA GARDU DISTRIBUSI KA 0819 PENYULANG MUMBUL,” Log. J. Ranc. Bangun dan Teknol., vol. 15, no. 3, p. 159, Mar. 2017, doi: 10.31940/LOGIC.V15I3.493.

S. D. Luqmantoro, S. Sujito, and R. Mucharam, “Mutasi Transformator Distribusi Di Blimbing Kota Malang Penyulang Ampeldento N1314 Dari 160 kVA Ke 250 kVA Untuk Menghindari Kerusakan Akibat Beban Lebih,” PoliGrid, vol. 3, no. 2, p. 57, 2022, doi: 10.46964/poligrid.v3i2.1715.

B. Badriana, J. Jordan, S. Salahuddin, S. Meliala, and K. Kartika, “ANALISIS PENEMPATAN RECLOSER GUNA MEMAKSIMALKAN KINERJA SISTEM TENAGA LISTRIK DI JARINGAN DISTRIBUSI 20 kV PADA PT. PLN (Persero) UNIT PELAKSANA PELAYANAN PELANGGAN (UP3) SIGLI,” J. Energi Elektr., vol. 10, no. 1, pp. 30–34, May 2021, doi: 10.29103/jee.v10i1.4984.

M. Rafi et al., “PENGARUH SUDUT DAYA PADA SISTEM DISTRIBUSI TEGANGAN MENENGAH JARINGAN KABEL DAN UDARA,” RELE (Rekayasa Elektr. dan Energi) J. Tek. Elektro, vol. 6, no. 1, pp. 24–28, Jun. 2023, doi: 10.30596/RELE.V6I1.15452.

E. Permata and I. Lestari, “MAINTENANCE PREVENTIVE PADA TRANSFORMATOR STEP-DOWN AV05 DENGAN KAPASITAS 150KV DI PT. KRAKATAU DAYA LISTRIK,” Pros. Semin. Nas. Pendidik. FKIP, vol. 3, no. 1, pp. 485–493, Nov. 2020.

A. Supriyadi, “HUBUNGAN PADA TRANSFORMATOR TIGA FASA,” Swara Patra Maj. Ilm. PPSDM Migas, vol. 7, no. 1, Dec. 2017.

M. S. Aihunan, H. L. Latupeirissa, and A. J. Kastanja, “PERAMALAN BEBAN PENYULANG WAYAME 2 PT. PLN (PERSERO) AREA AMBON MENGGUNAKAN METODE LEAST SQUARE,” J. ELKO (Elektrikal dan Komputer), vol. 2, no. 2, 2021.

V. Khaerunnisa, K. Usman, and M. A. Murti, “ID: 31 Prediksi Pemakaian Beban Listrik Menggunakan Metode Least Mean Square dan Compressive Sensing Prediction Of Electrical Power Usage Using Least Mean Square and Compressive Sensing,” no. November, pp. 227–240, 2020.

M. F. Hakim, S. Nurhadi, H. D. F. Amaral, and S. L. Hermawan, “Kapasitor Shunt Sebagai Korektor Tegangan Bus di Gardu Induk,” Elposys J. Sist. Kelistrikan, vol. 10, no. 1, pp. 30–35, Mar. 2023, doi: 10.33795/ELPOSYS.V10I1.915.

Sukamdi, H. M. Kristiana, M. H. Farizan, and M. R. F. Firmansyah, “Analisis Rencana Pemasangan Transformator Sisipan Untuk Mengatasi Overload dan Drop Voltage pada Penyulang Selogabus PT. PLN (Persero) ULP Bojonegoro Kota,” Elposys J. Sist. Kelistrikan, vol. 9, no. 3, pp. 127–133, Oct. 2022, doi: 10.33795/ELPOSYS.V9I3.646.

Downloads

Published

2024-06-21

How to Cite

Harrij Mukti K., Rachmat Sutjipto, & Vidiasih. (2024). Efektivitas Mutasi Transformator Dalam Mengatasi Fluktuasi Beban Pada Trafo Distribusi ULP Bululawang. Elposys: Jurnal Sistem Kelistrikan, 11(2), 98–103. https://doi.org/10.33795/elposys.v11i2.5187