Analisis Aliran Daya Reconductoring Saluran Transmisi Paiton Kraksaan-Probolinggo 150 kV Terhadap Saluran Yang Terimbas

Authors

  • Rohmanita Duanaputri Politeknik Negeri Malang
  • Ahmad Hermawan Politeknik Negeri Malang
  • Zulvina Arifah Politeknik Negeri Malang

DOI:

https://doi.org/10.33795/elposys.v9i2.618

Keywords:

Deviation analysis, PT.PLN, reconductoring, open circuit method

Abstract

This reconductoring is carried out using the open circuit method or a total blackout in a circuit where the conductor is being replaced by taking into account the stages determined by PT. PLN (Persero). So that the power flow in the system must be considered when these conditions take place for the sake of service reliability or system reliability using a power flow simulator application, namely ETAP software. The simulation voltage tolerance with actual conditions is 5%. Next, analyze the power flow on the affected transmission line which is directly connected to the Kraksaan – Paiton – Probolinggo 150 kV transmission line based on voltage drop, transmission line losses and loading from each stage. As well as calculating the power transfer capability after and before reconductoring. The results of the simulation show that the most significant anomaly (deviation that should not be) is that there is a critical point loading of up to 89.220% on the Probolinggo - Gondangwetan channel when reconductoring has been carried out except for the Paiton - Kraksaan1 transmission line. Meanwhile, the value of power transfer capability increased after reconductoring, where the Paiton-Kraksaan1 and Paiton-Kraksaan2 channels increased by 63.91 MW, the Kraksaan - Probolinggo1 channel increased by 67.95 MW, and the Kraksaan - Probolinggo2 channel increased by 63.461 MW from previously

References

S. Suripto, Buku Ajar Dasar Sistem Tenaga Listrik. Yogyakarta: Universitas Muhammadiyah Yogyakarta, 2014.

A. Arismunandar and S. Kuwahara, TEKNIK TENAGA LISTRIK, II. JAKARTA: PT PRADNYA PARAMITA, 2004.

C. Cekdin and T. Barlian, Transmisi Daya Listrik. Yogyakarta: ANDI, 2013.

D. S. Nabila and S. M. Salafia, “ANALISIS SUSUT DAYA DAN DROP TEGANGAN SETELAH PERUBAHAN KONFIGURASI DAN UPRATING SUTT MENJADI 150 KV PADA GI KEBONAGUNG-GI BLIMBING,” Politeknik Negeri Malang, 2020.

A. Hermawan, “DISTRIBUSI DAN TRANSMISI SISTEM TENAGA LISTRIK,” Malang: Politeknik Negeri Malang, 2008, p. 41.

Anonim2, Buku Pedoman Pemeliharaan Saluran Udara Tegangan Tinggi dan Ekstra Tinggi (SUTT/SUTET). JAKARTA: PT. PLN (Persero), 2014.

M. M. Effendi, “ANALISIS ALIRAN DAYA DAN KUALITAS DAYA MENGGUNAKAN PERFORMANCE INDEX AKIBAT UPRATING SALURAN TRANSMISI DARI 70 KV MENJADI 150 KV PADA SUBSISTEM PAITON–GRATI,” Politeknik Negeri Malang, 2020.

Hutauruk, “TRANSMISI DAYA LISTRIK,” 2nd ed., JAKARTA: ERLANGGA, 1990, pp. 54–55.

E. Mateescu, D. Marginean, G. Florea, S. I. A. Gal, and C. Matea, “Reconductoring using HTLS conductors. Case study for a 220 kV double circuit transmission LINE in Romania,” 2011, doi: 10.1109/TDCLLM.2011.6042242.

Anonim1, Peraturan Menteri Energi dan Sumber Daya Mineral Nomor: 03 Tahun 2007. 2007.

B. M. Sri, “ANALISIS AVAILABLE TRANSFER CAPABILITY (ATC) SALURAN TRANSMISI 150 KV PADA KINERJA OLS 1, OLS 2, DAN OLS 3 DI SUB SISTEM KRIAN IBT 3 & 4,” Politeknik Negeri Malang, 2019.

Downloads

Published

2022-10-28

How to Cite

Rohmanita Duanaputri, Ahmad Hermawan, & Zulvina Arifah. (2022). Analisis Aliran Daya Reconductoring Saluran Transmisi Paiton Kraksaan-Probolinggo 150 kV Terhadap Saluran Yang Terimbas. Elposys: Jurnal Sistem Kelistrikan, 9(2), 64–69. https://doi.org/10.33795/elposys.v9i2.618