Annealing effects on single-phase E-I transformer performance under nonlinear loads

Authors

  • Priya Surya Harijanto Politeknik Negeri Malang
  • Slamet Nurhadi Politeknik Negeri Malang
  • Chandra Wiharya Politeknik Negeri Malang
  • Satria Luthfi Hermawan Politeknik Negeri Malang
  • Bakti Indra Kurniawan Politeknik Negeri Malang
  • Divac Nabiel Akbar Politeknik Negeri Malang

DOI:

https://doi.org/10.33795/eltek.v24i2.10746

Keywords:

Annealing, Core Loss, E-I Transformer, Harmonic Distortion, Voltage Regulation

Abstract

Single-phase E-I transformers are widely used in power-conversion applications, including grid-connected flyback micro-inverters for solar photovoltaic systems, yet their performance often deteriorates due to high core loss and harmonic distortion generated by nonlinear loads. This study evaluated the effect of the annealing process on core loss, voltage regulation, energy efficiency, and voltage/current harmonic distortion of a single-phase E-I transformer under nonlinear loading. Three transformer samples were tested under no-load and nonlinear-load conditions (rectifier and inverter) before and after annealing at 180, 350, and 450 °C for 60 minutes, followed by harmonic-distortion measurement using a power logger on a flexible conveyor system and a single-phase induction motor. Annealing at 350 °C produced the most significant core-loss reduction, from 150.3 W to 110.6 W, while linear-load efficiency reached 97-98% and voltage regulation remained stable near 98%. Harmonic measurements showed voltage total harmonic distortion (THDv) of 5.8% on the flexible conveyor system and 5.6% on the induction motor without a variable speed drive, both below the 8% IEEE 519 limit, while individual current harmonic distortion (IHDi), current total harmonic distortion (THDi), and total demand distortion (TDD) also remained within the standard's safe margins. These findings indicate that medium-temperature annealing can improve the magnetic performance of the transformer core while keeping power quality within standard limits under nonlinear loading. The practical implication is that this annealing guideline can be adopted by small and medium-scale transformer manufacturers to improve energy efficiency without costly equipment investment.

References

Z. Zhang et al., "Effects of Annealing Temperature and Compaction Pressure on Magnetic Properties of Fe–Si Powder Cores Fabricated by an Improved Bluing Method," J. Supercond. Nov. Magn., vol. 31, no. 5, pp. 1507-1513, May 2018, doi: 10.1007/S10948-017-4358-0.

Y. Du, W. Zheng, and J. Zhang, "Modeling and Analysis of Leakage Flux and Iron Loss Inside Silicon Steel Laminations," Int. J. Energy Power Eng., vol. 5, no. 1, pp. 48-52, 2016, doi: 10.11648/J.IJEPE.S.2016050101.17.

P. Kühn, Y. Yang, G. Chen, S. N. Foster, H. Egger, and B.-X. Xu, "Multiphysics simulations of microstructure influence on hysteresis and eddy current losses of electrical steel," arXiv preprint, Feb. 2025. [Online]. Available: https://arxiv.org/abs/2502.01559v1

C. Zhou, S. Luan, J. Qiao, and H. Wang, "Effect of Normalizing Temperature on Microstructure, Texture and Magnetic Properties of Non-Oriented Silicon Steel," Metals, vol. 15, no. 2, p. 217, Feb. 2025, doi: 10.3390/MET15020217.

J. Yuan et al., "Effect of annealing time on microstructure and properties of high-strength non-oriented silicon steel with Nb addition," J. Mater. Res. Technol., vol. 36, pp. 3756-3772, May 2025, doi: 10.1016/J.JMRT.2025.04.056.

S. Nurhadi, A. D. Nofvowan, S. L. Hermawan, and B. S. Gumilang, "Pengaruh Variasi Proses Annealing pada Performa Core Losses Trafo 1 Fasa E-I," ELPOSYS: J. Sistem Kelistrikan, vol. 12, no. 2, pp. 138-143, Jun. 2025.

ASTM International, ASTM A912-20: Standard Practice for Heat Treatment of Electrical Steel, ASTM International, West Conshohocken, PA, 2020.

IEEE Std 519-2014/2019, IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems, Institute of Electrical and Electronics Engineers, New York, 2014/2019.

B. Mitra, A. Singhal, S. Kundu, and J. P. Ogle, "Analyzing Distribution Transformer Degradation with Increased Power Electronic Loads," in Proc. 2023 IEEE PES ISGT, Oct. 2022, doi: 10.1109/ISGT51731.2023.10066387.

M. H. Mohd Wazir et al., "Harmonics Assessment of Distribution Transformer with Photovoltaic Integration and Unbalanced Loads," Elektrika J. Electr. Eng., vol. 23, no. 1, pp. 81-87, Apr. 2024, doi: 10.11113/ELEKTRIKA.V23N1.504.

P. Osinski and P. Witczak, "Analysis of Core Losses in Transformer Working at Static Var Compensator," Energies, vol. 16, no. 12, p. 4584, Jun. 2023, doi: 10.3390/EN16124584.

X. Ma, R. Jia, C. Liang, H. Du, X. Dong, and M. Ding, "Study of Transformer Harmonic Loss Characteristic in Distribution Network Based on Field-Circuit Coupling Method," Sustainability, vol. 14, no. 20, p. 12975, Oct. 2022, doi: 10.3390/SU142012975.

I. Ziger, B. Trkulja, and Ž. Štih, "Determination of Core Losses in Open-Core Power Voltage Transformers," IEEE Access, vol. 6, pp. 29426-29435, 2018, doi: 10.1109/ACCESS.2018.2838446.

Downloads

Published

30-10-2026

How to Cite

[1]
P. S. Harijanto, S. Nurhadi, C. Wiharya, S. L. Hermawan, B. I. Kurniawan, and Divac Nabiel Akbar, “Annealing effects on single-phase E-I transformer performance under nonlinear loads”, eltek, vol. 24, no. 2, pp. 102–110, Oct. 2026.